    ♦Analog Output (including I2C output)
    (Ta = 25°C)
    Model No.
    Distance
    measuring range
    (cm)
    Features
    Absolute maximum ratings
    Electro-optical characteristics*1
    Vcc
    (V)
    Topr
    (°C)
    VOH
    (V)
    MIN.
    VOL
    (V)
    MAX.
    Dissipation current
    Operating
    (mA)
    4 to 50
    Infrared LED and CMOS image sensor with built-in signal processing circuit, compact size
    (18.9 × 8 × 5.2 mm), high-precision measurement, analog output
    –0.3 to +3.6
    –10 to +60
    VOUT (A) 1 = 0.3 to 0.8 V
    (at L = 50 cm),
    VOUT (A) 3 = 2.1 to 2.3 V
    (at L = 4 cm)
    MAX. 36
    4 to 50
    Infrared LED and CMOS image sensor with built-in signal processing circuit, compact size
    (18.9 × 8 × 5.2 mm), high-precision measurement, I2C output
    –0.3 to +3.6
    –10 to +60
    D1 = 45 to 55 cm
    (at L = 50 cm),
    D3 = 3 to 5 cm
    (at L = 4 cm)
    MAX. 36
    4 to 50
    Infrared LED and CMOS image sensor with built-in signal processing circuit, compact size
    (16.7 × 11 × 5.2 mm), high-precision measurement, analog / I2C output both compatible
    –0.3 to +5.5
    –10 to +60
    VOUT (A) 1 = 0.3 to 0.8 V,
    D1 = 45 to 55 cm
    (at L = 50 cm),
    VOUT (A) 3 = 2.1 to 2.3 V,
    D3 = 3 to 5 cm
    (at L = 4 cm)
    MAX. 36
    *1 Vcc = 5 V

    GP2Y0D805Z0F
    (GP2Y0D810Z0F,
    GP2Y0E02A
    (GP2Y0E02B)
    GP2Y0E03
    GP2Y0AF15 series
    GP2Y0AF30 series
    GP2Y0A21YK0F
    (GP2Y0D21YK0F,
    GP2Y0A41SK0F
    GP2Y0D413K0F:
    without mounting
    hole)
    GP2Y0A51SK0F
    GP2Y0D02YK0F
    (GP2Y0A02YK0F)
    GP2Y0A710K0F
    ※Notice
    In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
    *RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants (PBBs and PBDEs), with certain exceptions.
    Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.